1. SPECIFICATIONS
DATA G10
OUTDOOR UNITS
2 - 196
HP
I.
HYPER HEATING INVERTER SERIES
1. SPECIFICATIONS
 Model
PUHY-HP200YHM-A(-BS)
PUHY-HP250YHM-A(-BS)
Power source
3-phase 4-wire 380-400-415V 50/60Hz
3-phase 4-wire 380-400-415V 50/60Hz
 Cooling capacity
*1
kW
22.4
28.0
(Nominal)
*1
kcal / h
19,300
24,100
*1
BTU / h
76,400
95,500
Power input
kW
6.40
9.06
Current input
A
10.8-10.2-9.8
15.2-14.5-14.0
COP
kW / kW
3.50
3.09
Temp. range of
Indoor
W.
B.
15 to 24degC(59 to 75degF)
15 to 24degC(59 to 75degF)
cooling
Outdoor
D.
B.
-5 to 43degC(23 to 109degF)
-5 to 43degC(23 to 109degF)
 Heating capacity
*2
kW
25.0
31.5
(Nominal)
*2
kcal / h
21,500
27,100
*2
BTU / h
85,300
107,500
Power input
kW
6.52
8.94
Current input
A
11.0-10.4-10.0
15.0-14.3-13.8
COP
kW / kW
3.83
3.52
Temp. range of
Indoor
D.
B.
15 to 27degC(59 to 81degF)
15 to 27degC(59 to 81degF)
heating
Outdoor
W.B.
-25 to 15.5degC(-13 to 60degF)
-25 to 15.5degC(-13 to 60degF)
Indoor unit
Total capacity
50 to 130 % of outdoor unit capacity
50 to 130 % of outdoor unit capacity
connectable
Model / Quantity
P15 to P250 / 1 to 17
P15 to P250 / 1 to 21
 Sound pressure level (measured in anechoic room)
dB <A>
56
57
 Refrigerant
Liquid pipe
 mm(in.)
12.7(1/2) Brazed
12.7(1/2) Brazed
piping diameter
Gas pipe
mm(in.)
19.05(3/4) Brazed
22.2(7/8) Brazed
FAN
Type x Quantity
Propeller fan x 1
Propeller fan x 1
Air flow rate
m
3
 / min
225
225
L/s
3,750
3,750
cfm
7,945
7,945
Control, Driving mechanism
Inverter-control,Direct-driven by motor
Inverter-control,Direct-driven by motor
Motor output
kW
0.92 x 1
0.92 x 1
*3
External static press.
0 Pa (0 mmH
2
O)
0 Pa (0 mmH
2
O)
Compressor
Type x Quantity
Inverter scroll hermetic compressor
Inverter scroll hermetic compressor
Manufacture
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Starting method
Inverter
Inverter
Motor output
kW
5.3
6.7
Case heater
kW
0.045
0.045
Lubricant
MEL32
MEL32
External finish
Pre-coated galvanized steel sheets
Pre-coated galvanized steel sheets
<MUNSELL 5Y 8/1 or similar>
<MUNSELL 5Y 8/1 or similar>
External dimension HxWxD
mm
1,650 x 920 x 760
1,650 x 920 x 760
in.
65 x 36-1/4 x 29-15/16
65 x 36-1/4 x 29-15/16
Protection devices
High pressure protection
High pressure sensor, High pressure switch at 4.15MPa (601
psi)
High pressure sensor, High pressure switch at 4.15MPa (601
psi)
Inverter circuit (COMP.
 / FAN)
Over-heat protection,Over-current protection
Over-heat protection,Over-current protection
Compressor
Over-heat protection
Over-heat protection
Fan motor
Thermal switch
Thermal switch
Refrigerant
Type x original charge
R410A x 9.0kg (20lbs)
R410A x 9.0kg (20lbs)
Control
LEV and HIC circuit
LEV and HIC circuit
 Net weight
 kg(lbs)
220(486)
220(486)
Heat exchanger
Salt-resistant cross fin & copper tube
Salt-resistant cross fin & copper tube
HIC circuit (HIC: Heat Inter-Changer)
Copper pipe,tube-in-tube structure
Copper pipe,tube-in-tube structure
Defrosting method
Auto-defrost mode (Reversed refrigerant circle)
Auto-defrost mode (Reversed refrigerant circle)
 Drawing
External
WKB94R110
WKB94R110
Wiring
WKE79B230
WKE79B230
Standard attachment
Document
Installation Manual
Installation Manual
Accessory
Refrigerant conn. pipe
Refrigerant conn. pipe
 Optional parts
Joint: CMY-Y102SS-G2
Joint: CMY-Y102SS-G2
Header: CMY-Y104/108/1010-G
Header: CMY-Y104/108/1010-G
Remark
* Details on foundation work, duct work, insulation work, elec-
trical wiring, power source switch, and other items shall be re-
ferred to the Installation Manual.
* Details on foundation work, duct work, insulation work, elec-
trical wiring, power source switch, and other items shall be re-
ferred to the Installation Manual.
* Due to continuing improvement, above specifications may be
subject to change without notice.
* Due to continuing improvement, above specifications may be
subject to change without notice.
Note :
*1 Nominal cooling conditions (subject to JIS B8615-2)
*2 Nominal heating conditions (subject to JIS B8615-2)
Unit converter
Indoor :
27degCDB/19degCWB
(81degFDB/66degFWB)
20degCDB
(68degFDB)
 kcal
=kW x 860
BTU/h
=kW x 3,412
Outdoor :
35degCDB
(95degFDB)
7degCDB/6degCWB
(45degFDB/43degFWB)
cfm
=m
3
/min x 35.31
 lbs
=kg / 0.4536
Pipe length :
7.5m(24-9/16ft.)
7.5m(24-9/16ft.)
Level difference :
0m(0ft.
)
0m(0ft.)
*The specification data is
*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH
2
O, 6.1mmH
2
O).
subject to rounding variation.